Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Microbiol Spectr ; 11(3): e0005523, 2023 Jun 15.
Article in English | MEDLINE | ID: covidwho-2319646

ABSTRACT

Coronavirus disease 2019, caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), poses a considerable threat to global public health. This study developed and evaluated a rapid, low-cost, expandable, and sequencing-free high-resolution melting (HRM) assay for the direct detection of SARS-CoV-2 variants. A panel of 64 common bacterial and viral pathogens that can cause respiratory tract infections was employed to evaluate our method's specificity. Serial dilutions of viral isolates determined the sensitivity of the method. Finally, the assay's clinical performance was assessed using 324 clinical samples with potential SARS-CoV-2 infection. Multiplex HRM analysis accurately identified SARS-CoV-2 (as confirmed with parallel reverse transcription-quantitative PCR [qRT-PCR] tests), differentiating between mutations at each marker site within approximately 2 h. For each target, the limit of detection (LOD) was lower than 10 copies/reaction (the LOD of N, G142D, R158G, Y505H, V213G, G446S, S413R, F486V, and S704L was 7.38, 9.72, 9.96, 9.96, 9.50, 7.80, 9.33, 8.25, and 8.25 copies/reaction, respectively). No cross-reactivity occurred with organisms of the specificity testing panel. In terms of variant detection, our results had a 97.9% (47/48) rate of agreement with standard Sanger sequencing. The multiplex HRM assay therefore offers a rapid and simple procedure for detecting SARS-CoV-2 variants. IMPORTANCE In the face of the current severe situation of increasing SARS-CoV-2 variants, we developed an upgraded multiplex HRM method for the predominant SARS-CoV-2 variants based on our original research. This method not only could identify the variants but also could be utilized in subsequent detection of novel variants since the assay has great performance in terms of flexibility. In summary, the upgraded multiplex HRM assay is a rapid, reliable, and economical detection method, which could better screen prevalent virus strains, monitor the epidemic situation, and help to develop measures for the prevention and control of SARS-CoV-2.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , SARS-CoV-2/genetics , COVID-19/diagnosis , Sensitivity and Specificity , Polymerase Chain Reaction
2.
Biosaf Health ; 5(2): 101-107, 2023 Apr.
Article in English | MEDLINE | ID: covidwho-2306537

ABSTRACT

The recent outbreak of the coronavirus disease 2019 (COVID-19) pandemic and the continuous evolution of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) have highlighted the significance of new detection methods for global monitoring and prevention. Although quantitative reverse transcription PCR (RT-qPCR), the current gold standard for diagnosis, performs excellently in genetic testing, its multiplexing capability is limited because of the signal crosstalk of various fluorophores. Herein, we present a highly efficient platform which combines 17-plex assays with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS), enabling the targeting of 14 different mutation sites of the spike gene. Diagnosis using a set of 324 nasopharyngeal swabs or sputum clinical samples with SARS-CoV-2 MS method was identical to that with the RT-qPCR. The detection consistency of mutation sites was 97.9% (47/48) compared to Sanger sequencing without cross-reaction with other respiratory-related pathogens. Therefore, the MS method is highly potent to track and assess SARS-CoV-2 changes in a timely manner, thereby aiding the continuous response to viral variation and prevention of further transmission.

3.
Biosafety and health ; 2023.
Article in English | EuropePMC | ID: covidwho-2288828

ABSTRACT

The recent outbreak of the coronavirus disease 2019 (COVID-19) pandemic and the continuous evolution of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) have highlighted the significance of new detection methods for global monitoring and prevention. Although quantitative reverse transcription PCR (RT-qPCR), the current gold standard for diagnosis, performs excellently in genetic testing, its multiplexing capability is limited because of the signal crosstalk of various fluorophores. Herein, we present a highly efficient platform which combines 17-plex assays with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS), enabling the targeting of 14 different mutation sites of the spike gene. Diagnosis using a set of 324 nasopharyngeal swab or sputum clinical samples with SARS-CoV-2 MS method was identical to that with the RT-qPCR. The detection consistency of mutation sites was 97.9% (47/48) compared to Sanger sequencing without cross-reaction with other respiratory-related pathogens. Therefore, the MS method is highly potent to track and assess SARS-CoV-2 changes in a timely manner, thereby aiding continuous response to viral variation and prevention of further transmission.

4.
Emerg Microbes Infect ; 11(1): 2636-2644, 2022 Dec.
Article in English | MEDLINE | ID: covidwho-2121479

ABSTRACT

ABSTRACTA wave of Omicron infections rapidly emerged in China in 2022, but large-scale data concerning the safety profile of vaccines and Coronavirus disease 2019 (COVID-19) infection features in liver transplant (LT) recipients have not been collected. Therefore, the aim of this study was to assess the protectiveness and safety profile of the inactivated vaccines in LT patients against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) Omicron variant infections. A multi-centre retrospective study was conducted in a cohort with a history of liver transplantation. A total of 1881 participants (487 vaccinated and 1394 unvaccinated patients) were enrolled from seven centres in China. Fourteen of the participants were infected by Omicron, and 50% patients had over 14 days of viral shedding duration. The protection rate of COVID-19 vaccinations to Omicron was 2.59%. The three breakthrough infections occurred more than 6 months after fully vaccinated. A total of 96 (19.7%) vaccinated patients had adverse events, including fatigue, myalgia, liver dysfunction, swelling, and scleroma. There were more Grade 3 adverse events in the preoperative vaccination group than those in the postoperative vaccination group. Inactivated whole-virion SARS-CoV-2 vaccines are safe in patients with post-liver transplantation. The efficacy of inactivated vaccines decreases after 6 months of vaccination, it is recommended that liver transplant patients get boosted vaccinations as early as possible even when they are fully vaccinated. Although clinical manifestations of Omicron infections were mild in LT patients, unvaccinated patients might have a higher risk of liver dysfunction during infections.


Subject(s)
COVID-19 Vaccines , COVID-19 , Liver Transplantation , Humans , COVID-19/prevention & control , COVID-19 Vaccines/adverse effects , Retrospective Studies , SARS-CoV-2 , Vaccination , Vaccines, Inactivated/adverse effects
5.
Microb Biotechnol ; 15(6): 1883-1894, 2022 06.
Article in English | MEDLINE | ID: covidwho-1714095

ABSTRACT

Coronavirus disease 2019 (COVID-19), which is caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has recently posed a significant threat to global public health. The objective of this study was to develop and evaluate a rapid, expandable and sequencing-free high-resolution melting (HRM) approach for the direct detection and classification of SARS-CoV-2. Thirty-one common pathogens that can cause respiratory tract infections were used to evaluate the specificity of the method. Synthetic RNA with serial dilutions was utilized to determine the sensitivity of the method. Finally, the clinical performance of the method was assessed using 290 clinical samples. The one-step multiplex HRM could accurately identify SARS-CoV-2 and differentiate mutations in each marker site within approximately 2 h. For each target, the limit of detection was lower than 10 copies/reaction, and no cross-reactivity was observed among organisms within the specificity testing panel. The method showed good uniformity for SARS-CoV-2 detection with a consistency of 100%. Regarding the clade classification performance, the results showed good concordance compared with sequencing, with the rate of agreement being 95.1% (78/82). The one-step multiplex HRM method is a rapid method for SARS-CoV-2 detection and classification.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , Humans , Polymerase Chain Reaction , SARS-CoV-2/genetics , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL